Demineralization units without pretreatment
Demineralization is the removal of dissolved solids in water by ion exchange. The ECOMAX demineralizer does not require special pretreatment of the incoming water to achieve the quality of demineralized water. The units are used in many areas, including the production of wash water, process water, boiler water, etc.
Demineralization units are two-column systems in which water first passes through a cation exchange column and then passes through an anion exchange column.
Where is demineralization used?
Product overview
Our product range includes a large number of standard plants, designed and manufactured in-house. The starting point is our modular standard system, which offers high flexibility, high operational reliability and short delivery times. Each solution can be tailored to the specific application by selecting materials, instrumentation and control system - based on our combined know-how.
Plant design
Demineralization plants are available with semi-automatic or automatic regeneration. Semi-automatic demineralization plants require manual regeneration initiation, while an automatic plant initiates regeneration when the demineralizer capacity is exhausted.
Contact your local sales and service office for further information, data sheets and instructions.

Automatic
countercurrent
| Type: | DMCE |
| Modules: | 3 |
| Performance up to: | 13 m3/h |
| Качество: | 2-5 µS/cm |

Automatic
Forward flow
| Type: | DME |
| Modules: | 7 |
| Performance up to: | 5 m3/h |
| Quality: | 5-20 µS/cm |

Automatic
direct flow
| Type: | DMHE |
| Modules: | 5 |
| Performance up to: | 20 m3/h |
| Quality: | 5-20 µS/cm |

Semi-automatic
direct flow
| Type: | DMS |
| Modules: | 8 |
| Performance up to: | 5 m3/h |
| Quality: | 5-20 µS/cm |
High water quality and low chemical consumption thanks to counter-current regeneration
With counter-current regeneration, the flow direction during operation and regeneration is opposite. This ensures more efficient regeneration, resulting in lower chemical consumption and improved water quality by up to 1-5 μS/cm. Automatic counter-current regeneration is available in our DMCE series demineralizers.
To ensure balanced use of the plant and optimize chemical consumption for the neutralization process, the cation exchanger filter housing is often smaller than the anion exchanger filter housing.
Contact us for technical data or additional information.

Reliable demineralization units
Anti-corrosion housings
The filter housing is made of steel and can withstand pressure fluctuations. It has a surface coating of PPA, a high-performance polyethylene coating applied at the factory. Thus, the filter housings combine the strength of steel with the strong anti-corrosion properties of PPA (C5-M).

Control valve
Our patented five-way valve is designed specifically for ECOMAX units. It is made of high-quality synthetic material and has a small number of moving parts. This ensures reliable operation, a long service life and minimal maintenance costs.

Piping system
The supplied piping system is made of PVC as standard and is resistant to corrosion and chemicals. All gaskets and sealing rings are made of silicone-free materials. The system is also available in other materials such as PP and PVDF.

Standard Control
Each demineralization plant is equipped with a standard control panel. Our controls are specially designed and individually programmed by our control engineers.

Demineralized water with low conductivity
FSD demineralization units are used for additional purification of demineralized water. By treating demineralized water with low carbon dioxide content, conductivity of less than 0.1 μS/cm at 10°C can be achieved.

Get the optimal solution
The choice of installation depends on the area of application, quality and consumption of water. We are at your service to find the optimal solution based on our know-how. Fill out the form and we will contact you.