Construction of sewage treatment plants (STP)

Sewage Treatment Plants

These sewage treatment plants are compact, modular biological treatment systems designed for domestic wastewater.

Polypropylene units are available with capacities ranging from 3 to 200 m³/day.
The biological treatment station consists of factory-manufactured modules designed for underground installation.
The system’s process modules are installed according to the layout plan, connected to the domestic sewage network and to each other via piping, and linked to air ducts and electrical cables.
Wastewater is transferred between process compartments using airlifts; an emergency overflow system is also provided.
The quality of the treated effluent meets current regulatory standards, allowing for discharge onto the ground or into fishery water bodies, or for use in technical applications. Wastewater treatment performance indicators:

pH: inlet 6.5–8.5, outlet 6.5–8.4
Suspended solids: inlet up to 400 mg/L, outlet 6–10 mg/L
BOD (total): inlet up to 450 mg O₂/L, outlet 3 mg O₂/L
Petroleum products: inlet 0.2 mg/L, outlet 0.05 mg/L
Ammonium nitrogen: inlet 35 mg/L, outlet 0.4 mg/L
Nitrogen: inlet up to 56 mg/L, outlet 0.02 mg/L
Nitrate nitrogen: outlet 9.1 mg/L
Phosphates (as P₂O₅): inlet 5 mg/L, outlet 0.2 mg/L
Surfactants (synthetic): inlet 20 mg/L, outlet 0.1 mg/L
COD: inlet 650 mg O₂/L, outlet 15 mg O₂/L
Fats/Grease: inlet 25 mg/L, outlet 0.1 mg/L

Biological treatment plant supply package

Underground sewage treatment facilities. The treatment process units feature a rectangular footprint, are manufactured from high-strength polypropylene, and are equipped with access shafts for maintenance.
Auxiliary equipment is housed in a sealed underground unit or an above-ground container module (upon request).
The treatment facilities operate automatically, eliminating the need for constant on-site maintenance personnel. Wastewater Treatment Technology for Sewage Treatment Plants

The plant operates based on an advanced biological wastewater treatment method.

Contaminated wastewater enters the receiving chamber, which is equipped with a debris-trapping basket (with 10–15 mm openings) to capture coarse particles. The receiving chamber features a deflector baffle to retain settled mineral contaminants (such as sand). A disc aerator is installed in the receiving tank to neutralize (strip out) chlorine-containing impurities and wash mineral contaminants.
Next, the wastewater passes through a sorption filter medium into the main tank. The receiving chamber and the tank together form an equalization tank, which balances out surge loads and stabilizes wastewater temperature.
A submersible pump then delivers the wastewater to the distribution system. The effluent is sprayed onto the biological media and flows down into the anaerobic settling zone, where denitrification takes place.
From the anaerobic reactor, the wastewater flows into an aerobic reactor equipped with an aeration system. Intermittent fine-bubble aeration facilitates the oxidation of organic matter. Nitrogenous pollutants are also removed (via nitrification) within the aerobic reactor.
Final effluent polishing takes place in an aerobic biofilter. As contaminated water passes through the biofilter media, it deposits undissolved impurities that did not settle in the primary clarifiers, as well as colloidal and dissolved organic substances that are adsorbed by the biofilm. Microorganisms inhabiting the biofilm oxidize the organic matter to obtain energy for their metabolic processes, utilizing a portion of the organic matter for their own growth. Thus, organic substances are removed from the wastewater while active biomass accumulates on the biofilters. Spent and dead biofilm is washed off by the wastewater flow and carried out of the biofilter. Atmospheric oxygen required for the biochemical process is supplied to the filter media via forced aeration. Excess sludge is periodically pumped into a sludge storage tank.
After passing through the biofilter, the wastewater flows through a mechanical filter—using expanded clay media to prevent the carryover of sludge—into a treated water settling tank. As it arrives, the wastewater enters the buffer tank of the tertiary treatment and disinfection unit. This tank is equipped with level sensors to enable automatic operation of the filtration equipment.
Biologically treated wastewater is pumped from the intermediate tank to a direct electrolysis unit for further processing. Disinfection via direct electrolysis is a form of oxidative water treatment; however, it differs fundamentally from conventional disinfection methods in that the oxidizing agents are generated from the water itself rather than being introduced from an external source, and they revert to their original state after performing their function. The efficiency of water disinfection by direct electrolysis is several times higher than that of chemical methods.

Direct electrolysis of water facilitates the removal of color, hydrogen sulfide, and ammonium from the source water. Direct electrolysis requires neither dosing pumps nor the use of chemical reagents.
Following direct electrolysis treatment, the wastewater flows into a sand filter to remove suspended solids.
The treated water discharges from the treatment plant under pressure.

Feedback