Advantages of reinforced concrete structures:
Ease and simplicity of installation—using well-established procedures and technical documentation—combined with the ready availability of raw materials, make reinforced concrete a preferred choice over other materials;
Manufacturing versatility allows for the creation of diverse shapes and structural designs to suit various reservoir purposes and applications;
Exceptional durability ensures a long service life, eliminating the need for major overhauls for many years;
Low cost makes reinforced concrete structures a viable option even for developers with very limited budgets;
Superior fire resistance compared to other materials makes these reservoirs ideal for storing water for firefighting purposes;
Resistance to aggressive environments allows for the use of reinforced concrete reservoirs across various industries and sectors of human activity; consequently, wastewater treatment facilities are frequently constructed using this material;
High resistance to static and dynamic loads enables the use of reinforced concrete in regions with varying levels of seismic activity.
Specifications for reinforced concrete components include:
coefficient of variation of mortar mixture strength (%),
required strength of the mortar mixture in MPa (kgf/cm²),
type and quantity of additives (e.g., for winter application) in kg (L),
material class based on the specific effective activity of natural radionuclides,
maximum aggregate size (mm).
Standard Configuration
The standard configuration includes mating flanges for connections to inlet and outlet piping, as well as maintenance access shafts, manholes, covers, ladders, service platforms, and debris collection baskets. Optional Features
sludge level sensor (e.g., for sand or petroleum products),
inlet flow meter,
outlet flow meter,
gas analyzer,
aerators (tubular, disc, or plate types),
debris collection devices (screens, baskets),
mixers to prevent stagnation and siltation,
spargers to prevent stagnation and siltation,
piping and fittings (pump guide rails for lowering and lifting, shut-off valves—globe valves, ball valves, gate valves),
pump assembly for fluid transfer (for further treatment or discharge),
baffles to create specific functional zones (sedimentation, mixing in accordance with the process flow, flow deflectors).
Installation
Installation is carried out in accordance with the operation manual, which is prepared by the supplier and provided with the equipment. Installation services may encompass a full range of activities, including:
construction and installation work (earthworks, concrete work),
installation of the tank itself,
installation of the roof, hatches, and ventilation nozzles,
installation of process equipment,
installation of piping and shut-off valves,
installation of electrical power equipment (pumps, control panels, level sensors),
connection to existing utility networks (water supply, sewage, storm drainage, electrical),
commissioning.
commissioning of the installed equipment,
individual and integrated equipment testing, bringing the system to standard operating mode in accordance with the technical specifications provided in the equipment documentation and achieving the performance metrics listed in the equipment passports,
training the client’s personnel on maintenance and operation rules and methods,
training the client’s personnel on procedures for maintaining operational logs.
Warranty and Service
The warranty period for the supplied equipment is specified in the warranty certificates handed over to the client along with the equipment. The service life warranty for the assembled glass-fused-to-steel tanks is 20 years. Scheduled maintenance is carried out according to a program prepared by the supplier. This program is developed based on the specific characteristics of the process layout at the client’s site and the client’s individual operational data. The maintenance program may include the following types of work:
checking tank tightness,
verifying flow meter accuracy,
checking the operating condition of pumping equipment,
verifying that actual pump activation frequency matches specifications,
checking the control panel for proper operation,
verifying signal functions (e.g., audible and visual alarms),
replacing worn parts and assemblies.